Nominal Size - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Specifies a branch bore limit to suppress dimensions.

Type a value in the range 0-999. The value that you enter must be in millimeters or 1/16 inches, depending on the bore units setting. Branches that have a bore less than or equal to the specified value are not dimensioned. In the example, the branch has a bore less than the Nominal Size setting. Consequently, it is not dimensioned.

Defines:

Option Switch - 81, Pos 4-6
I-Configure - Drawing.Dimensions.BranchBoreLimit

  • To dimension all branches, type 0.

  • Isogen does not suppress branch dimensions for any branch that contains pipe or pipe block.

  • Isogen treats fixed length pipe as a component. As such, branch dimensions are suppressed.

  • Nominal Size can work independently of or in conjunction with Component Count, depending upon your requirements.

  • This property is not available for Smart 3D cable tray and Smart 3D HVAC models.