Alternative Texts - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Where applicable, each AText description includes its respective default value. If a default value is not specified, the AText is normally left blank.

For each AText, three options are available:

  • <Default> uses the default AText value.

  • <Suppress> suppresses the AText value.

  • <Edit value> modifies the AText value with the user-specified entry.

ATexts -460 to -469 are used for the identification of external reference items when using the reference dimension facility. Any associated text elements are automatically prefixed or appended, as appropriate, to the specified AText element. The dollar character ( $ ) causes a new line to be plotted and the question mark character ( ? ) is where the software edits the element name to derive the full text string.

Ref Beam Label

Identifies horizontal steel-work element (SKEY=HST*). The default value is BEAM$?.

AText ID:

-460

? Value:

Reference item tag

$ Supported:

Yes

Ref Column Label

Identifies vertical steel-work element (SKEY=VST*). The default value is COLUMN$?.

AText ID:

-461

? Value:

Reference item tag

$ Supported:

Yes

Ref Building Label

Identifies the centerline of a building (SKEY=BLD*). The default value is ?$BUILDING.

AText ID:

-462

? Value:

Reference item tag

$ Supported:

Yes

Ref Equipment Label

Identifies the centerline of equipment (SKEY=EQU*). The default value is CL EQUIPMENT$?.

AText ID:

-463

? Value:

Reference item tag

$ Supported:

Yes

Ref Pipeline Label

Identifies the centerline of pipeline (SKEY=PIP*). The default value is CL PIPELINE$?.

AText ID:

-464

? Value:

Reference item tag

$ Supported:

Yes

Ref Floor Label

Identifies the specified floor level (SKEY=FLR*). The default value is ?$FLOOR.

AText ID:

-465

? Value:

Reference item tag

$ Supported:

Yes

Ref Wall Label

Identifies the specified wall position (SKEY= WAL*). The default value is ?$WALL>

AText ID:

-466

? Value:

Reference item tag

$ Supported:

Yes

Ref Grid Label

Identifies the project grid line (SKEY=GRD*). The default value is GRID$?.

AText ID:

-467

? Value:

Reference item tag

$ Supported:

Yes

Ref Misc Label

Used for miscellaneous user-specified elements (SKEY=XXX*). The default ? character causes any identification name associated with the miscellaneous reference to be used when no other AText setting is made.

AText ID:

-468

? Value:

Reference item tag

$ Supported:

Yes

Reference Point Label

Identifies reference dimension item coordinates. The default value is REFERENCE POINT.

AText ID:

-469

? Value:

None

$ Supported: