Site Identifier Style - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the enclosure style for site assemblies on the isometric drawing.

Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • None displays no box enclosure.

  • Diamond Ended displays a diamond-ended box enclosure.

  • Round Ended displays a round-ended box enclosure.

  • Triangular displays a triangular-shaped enclosure.

  • Diamond displays a diamond-shaped enclosure.

  • Rectangular displays a rectangular-shaped enclosure.

  • Circle displays a circular-shaped enclosure.

  • Double Circle displays a circular-shaped enclosure inside another circle.

  • Ellipse displays an elliptical-shaped enclosure.

Defines:

Option Switch - 79, Pos 3
I-Configure - Drawing.Format.SiteAssemblyIDEnclosure

  • The site assembly uses AText -478, default J--such as J1 or JA--to prefix the flange assembly identification.