Tap on Pipe - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the dimensioning of tapped branches on pipe-type components, such as elbows, tees, and pipe.

Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • None turns off dimensions for tapped branch dimensions.

  • Full turns on tapped branch dimensions.

  • Pipe Only turns off tapped branch dimensions, except for those on pipe and pipe-type components.

Defines:

Option Switch - 121, Pos 2
I-Configure - Drawing.Dimensions.TapOnPipe