Alternative Texts - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Where applicable, each AText description includes its respective default value. If a default value is not specified, the AText is normally left blank.

For each AText, three options are available:

  • <Default> uses the default AText value.

  • <Suppress> suppresses the AText value.

  • <Edit value> modifies the AText value with the user-specified entry.

Screwed End Label

Plots an indicator that points to a pipe end that has been set to screwed in the pipeline input data file. The default value is SCREWED END.

AText ID:

-229

? Value:

None

$ Supported:

No

Screwed Erection Callout

Sets the output text as a message on screwed erection (construction) fittings. This AText is blank by default.

AText ID:

-286

? Value:

None

$ Supported:

No

Pipeline Change Label

Denotes the positions of a change in the pipeline reference or system isometrics. The default value is PIPE.

AText ID:

-288

? Value:

None

$ Supported:

No

Tangential Connection Label

Identifies tangential connections. In cases where the tapping point method is used, the existing tapping connection message (AText -451) is not output. The default value is TANGENTIAL CONNECTION.

AText ID:

-388

? Value:

None

$ Supported:

No

Offset Connection Label

Identifies offset connections. In cases where the tapping point method is used, the existing tapping connection message (AText -451) is not output. The default value is OFFSET CONNECTION.

AText ID:

-389

? Value:

None

$ Supported:

No

Connection Origin Label

Identifies tangential/offset connections. In cases where the tapping point method is used, the existing tapping connection message (AText -451) is not output. The default value is FROM ? ORIGIN.

AText ID:

-390

? Value:

None

$ Supported:

No

Unadjusted Welds

Indicates that a fitting-to-fitting weld or connection has not caused a cut pipe length adjustment to accommodate a weld root gap or weld shrinkage.

AText -391 is triggered when weld gaps are requested in the isometric drawing style .wdf file, but Isogen is unable to adjust any pipe length. This situation can occur when the weld is between two fittings.

AText ID:

-391

? Value:

None

$ Supported:

No

Fab Site Assembly Prefix

Used on the isometric drawing in conjunction with fabrication site assembly identifier. The default value is J.

AText ID:

-429

? Value:

None

$ Supported:

No

Offshore Site Assembly Prefix

Used on the isometric drawing in conjunction with offshore site assembly identifier. The default value is J.

AText ID:

-430

? Value:

None

$ Supported:

No

Tapping Connection Label

Is output along with coordinate values at the tapping point on a user-specified fitting. Requires Option Switch 122 to be set to 1 for tapping coordinates that are output on the isometric drawing. The default value is TAPPING CONNECTION.

AText ID:

-451

? Value:

None

$ Supported:

No

Undeveloped Branch Label

Indicates undeveloped set-on tees and olets, which have no branch leg and are indicated on dotted form on the pipeline, where the intended branch connection is in a skewed direction. A system-generated direction word is appended. The default value is CONNECTION ORIENTATION.

AText ID:

-454

? Value:

None

$ Supported:

No

Thickness Label

Shows thickness of a penetration plate on the drawing.

AText ID:

-459

? Value:

Penetration Plate Thickness

$ Supported:

Yes

Flange Assembly Prefix

The site assembly uses the AText -478 default value J, such as J1 or JA, to prefix the flange assembly identification. The default value is J.

AText ID:

-478

? Value:

Assembly Number

$ Supported:

Yes