Tap Branch Dimension - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the dimensioning of tee and tap branches to allow dimensioning to the edge of pipe.

Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • CentreLine originates dimensions from the centerlines of the main run.

  • TapAndSetOnStartPoint dimensions to the edge of pipe.

  • TapStartPoint defines tap dimensions only.

Defines:

Option Switch - 81, Pos 9
I-Configure - Drawing.Dimensions.TapBranchDimension

For Smart 3D cable tray isometric drawings and Smart 3D HVAC isometric drawings, Tap Branch Dimensions allows dimensioning of tee and tap branches to the edge of cable tray or duct, respectively.