Set the config item TRANS_CC_WASHER to YES to apply the logic described above when exporting the WasherPartData sheet or PipingCommodityMatlControlData part filter sheet.
WasherPartData
If the config item PD_WASHER_TRANS_LEVEL is set to IDENT, the commodity code is appended with the bolt diameter and the washer thickness values, separated by an underscore. The bolt diameter and the washer thickness values are fetched from the ident input_1 (bolt diameter) and input_2 (washer thickness).
PipingCommodityMatlControlData
If the config item PF_TRANSLATION_LEVEL is set to IDENT or CC_OR_IDENT, the values to be appended to the washer commodity codes are to be fetched from the ident inputs. When the config item is set to CC_OR_IDENT, this new logic applies only to the records at the ident level.
The washer commodity codes are identified by the assignment of parts to the WasherPartData sheet on the Item Mappings screen.