You can configure work steps for a carbon steel pipe with a pipe size of 0.25 meters using a standard thickness as seen in the following example.

First, you can define the pipe data for the carbon steel pipe on the rate table tab of the ROP Configuration.xlsm workbook. The following image highlights the details for the example carbon steel pipe.

The component class definitions for the pipe are P3DPipe, P3DPipeRun, PDS_Dwg_Pipe, and PDS_Dwg_PipeRun. The size is 0.25 using unit of measurement (UoM) of meters. Its material is carbon steel with a standard thickness.

When you add the component with the component class of P3DPipe, P3DPipeRun, PDS_Dwg_Pipe, and PDS_Dwg_PipeRun to an Installation IWP, the work step Install is added with a rate of 0.520. When you add the component class to a Testing IWP, the work step Pressure Test is added with a rate of 0.200.