Pipe Attachment 1 Properties - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports Data Driven Assembly Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
12.1 (2019)

These properties specify and customize the attachments in the support.

The following properties are applicable to I Frame and T Frame type.

IJUAhsFrPipeAtt1::PipeAtt1Part

Specifies the part number or part class for the first pipe attachment. For example, U-Bolt part number can be used as PipeAtt1Part. To select the part number using PipeAtt1Rule, do not type any value for this property.

IJUAhsFrPipeAtt1Rl::PipeAtt1Rule

Defines an HgrSupportRule that returns a pipe attachment part number. The hanger rule must exist in the catalog; it can be the name of a rule or a rule ProgID. To select the part number directly using PipeAtt1Part, do not type any value for this property.

IJUAhsFrPipeAtt1Qty::PipeAtt1Quantity

Specifies the number of PipeAtt1Part to be included in the support. Usually, 1 or 2.

IJUAhsFrPipeAtt1Offset::PipeAtt1Offset

Specifies the offset value for PipeAtt1Part along the pipe.