Add Revisions to Specification Sheets - Intergraph Smart Instrumentation - Training - Intergraph Process, Power & Marine Documentation

SmartPlant InstrumentationTutorial

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Training
Smart Instrumentation Version
2016 SP1 (11.0.1)
Smart Instrumentation Web Version
(none)
  1. Open the specification for tag 101-FE-201.

  2. Click to open the Revisions dialog box.

  3. Click New to add a revision to the specification sheet.

  4. Click OK to save the revision and close the dialog box.

  5. Close the specification sheet.

  6. When prompted to save data, click Yes.

  7. Open the specification sheet for tag 101-FE-100.

    You may see a message indicating that process data has been changed. Select Do not remind me again and click OK to continue.

  8. Click to open the Revisions dialog box.

  9. Enter revision data as follows:

    1. Select Revision method 0, 1, 2… and click New.

      When you first select a revision numbering method, several options are available to you, including preliminary revisions (designated by P0, P1, P2…). Once you select one of the other revision methods, you will not be able to return to the preliminary revision method and this option will be disabled.

    2. In the Description field, type For Design.

  10. When completed, click OK to return to the specification sheet.

  11. Click (Save).

  12. Make the changes to the following tag number properties in the specification sheet:

    Property

    Initial Value

    Changed Value

    Service

    Feed from V8

    Feed from V8-A

    Fluid

    Lean Feed

    Vapor Feed

    State

    Liquid

    Gas/Vapor

  13. Click (Save).

  14. When prompted to re-archive the specification, click No.