Connect the Analog Input Cable to the DCS Side - Intergraph Smart Instrumentation - Training - Intergraph Process, Power & Marine Documentation

SmartPlant InstrumentationTutorial

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Training
Smart Instrumentation Version
2016 SP1 (11.0.1)
Smart Instrumentation Web Version
(none)
  1. In the Domain Explorer, right-click the 101-DCS-001 DCS panel, and on the shortcut menu, click Actions > Connection.

  2. Make sure that in the Terminal strip list, the following terminal and its parent hierarchy is selected: 101-DCS-001, File Number 1, 1, 8 CH AI, TB1.

  3. In the Cables folder of Domain Explorer, select cable C-101-MR-DCS-001 and drag it to the left side of terminal 1+v.

  4. On the Cable Connection Definition dialog box, click the End 1 (DCS) option button and define the other options as shown.

  5. Click Connect to make the connection.

    The Connection window now reopens displaying the cable connection to the DCS:

    The wires for sets Pr 1, Pr 2, and Pr 7 include tag numbers because you have already made I/O assignments for these tags. Scroll down to Pr 7 and view the wire names.

  6. Keep the Connection window open.