These properties specify and customize the attachments in the support.
The following properties are applicable to I Frame and T Frame type.
IJUAhsFrPipeAtt1::PipeAtt1Part
Specifies the part number or part class for the first pipe attachment. For example, U-Bolt part number can be used as PipeAtt1Part. To select the part number using PipeAtt1Rule, do not type any value for this property.
IJUAhsFrPipeAtt1Rl::PipeAtt1Rule
Defines an HgrSupportRule that returns a pipe attachment part number. The hanger rule must exist in the catalog; it can be the name of a rule or a rule ProgID. To select the part number directly using PipeAtt1Part, do not type any value for this property.
IJUAhsFrPipeAtt1Qty::PipeAtt1Quantity
Specifies the number of PipeAtt1Part to be included in the support. Usually, 1 or 2.
IJUAhsFrPipeAtt1Offset::PipeAtt1Offset
Specifies the offset value for PipeAtt1Part along the pipe.