Meaning: The connected end of the supported member and the supporting surface port were expected as input, and the end port count was not two, resulting in incorrect placement of the general surface connection. This error is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Member Assembly Connections.

  4. Select the assembly connection in error.

  5. Click Delete ICON Remove.

  6. Click Place Assembly Connection .

  7. Select the frame connection.

  8. Clear the By Rule option.

  9. Select More from the Type box.

  10. Select Member End Assembly Connection > General Surface Assembly Connection > GeneralSurfaceAsmConn_1.

  11. Click OK.

  12. Click Finish.