12

The pressure rating should be equal to, or larger than the design pressure of the system. In many instances, larger pressures can be tolerated than the rated pressure shown. In many small diameter expansion joints, the same bellows is used in 50, 150, and 300 psi-rated joints. The CAESAR II modeler contains the true minimum pressure limits for all bellows in the database and checks the maximum pressure in the line (as specified) against the allowed pressure. This allows you to select a smaller joint with more flexibility for certain applications.