Load Cases - Input Tab - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Specifies the nozzle load cases.

Load cases work similarly for all equipment types.

SHARED Tip Control-click an undisplayed nozzle load cases item in the left pane to display load cases for both nozzles in one Load Cases tab.

Add LC ICON Add Case

Adds a load case. Select one of the following:

Import Load Cases - Displays the Select Load Cases dialog box, where you select one or more load cases defined in the .c2 model file defined for the CAESAR II Output File at the node defined for the CAESAR II Node Number. Each load case displays on a row of the grid. The load cases remain linked to the model and display in the Link column.

Add Custom - Adds a blank row. You then manually add load case values. The default value for Number is nu. The default value for Name is CASE USER n.

Delete LC ICON Delete Case

Deletes the load case on the selected row.

Copy

Copies one or more selected rows.

Paste

Pastes one or more copied rows.

A copied imported load case converts to a custom load case when pasted.

Refresh Linked Cases

Updates linked load cases (displaying in the Link column) to the latest values in the .c2 model file defined for the CAESAR II Output File.

Use this option when you change your CAESAR II file and you want to refresh the linked equipment load cases.

In the Equipment pane, you can also right-click > Refresh Linked Cases.