FDBR - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

FDBR is similar to Code-Specific Settings in most requirements. For more information, see Code-Specific Settings.

Calculate reinforced tees using FDBR

FDBR limits the pad thickness to a maximum equal to the header thickness. If you enter a pad thickness that is greater than the header thickness, the software overrides it with the header thickness.

Calculate reduced intersections using FDBR

Treat intersections similar to ASME NC. For more information, see ASME NC.

Calculate butt welds using FDBR

Use either 1.0 or 1.8 depending on the thickness.

Calculate flexibility analysis using FDBR

You must use the Hot Modulus of Elasticity in your flexibility analysis.

Calculate the expansion case allowable stress using FDBR

Wen computing the expansion case allowable stress,you must include the ratio of Ehot to Ecold. You can override the software-computed ratio by manually entering a value for Fac.

Calculate reducers using FDBR

The value for the flexibility factor is 1.0 and the equation to calculate reducer SIFs is:

2.0 max or 0.5 + .01*alpha* SQRT(D2/t2)

Where:

D1 - Diameter of the Large End

t1 - Thickness of the Large End

D2 - Diameter of the Small End

t2 - Thickness of the Small End

Alpha - Reducer Cone Angle in Degrees

When not entered:

Alpha = atan[ 0.5 * (D1-D2) / (0.60 * length of the reducer element) ]