Message
A Flanged Plate exists without the start points defined.
Or
A Flanged Plate exists without the end points defined.
Severity
Crucial.
Detailed Description
A Plate (Bracket) associated to a Flanged Plate Active Entity and a symbol is missing the relationship to the start or end points.
Possible Cause
Possible causes include:
-
Symbol inputs not correctly defined.
-
Transaction aborted during definition of the Flanged Plate.
-
Unknown.
Possible Impacts
The flange will not be processed, and errors may occur.
What You Should Do
-
Verify that the symbol being used is properly defined.
-
Modify the plate being flanged by redefining the symbol or attempting a recomputation.
-
Re-run the DB Integrity check.
-
If the problem still exists and the plate is as expected (needed), report the situation to Smart 3D Support. Revisions may be necessary.