Message
Member part has more than one attached cross section occurrence.
Severity
Normal.
Detailed Description
Every member part has one cross section occurrence that defines the projected profile for the solid. A member part cannot have more than one cross section occurrence; otherwise, it is ambiguous as to which section to project along the axis to define the member part solid geometry.
Possible Cause
Unknown.
Possible Impacts
Any manipulation of the member part will fail.
What You Should Do
No action is required.