Ult Tensile Stress - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Enter the temperature dependent stress value.

Typical units (depending on your unit system):

  • lb/in2

  • KPa

  • N/mm²

This value varies by piping code.

BS 806

Mean stress to failure for design life at temperature.

Swedish Method 1

Creep rupture stress at temperature.

Stoomwezen

Rrg average creep stress to produce 1% permanent set after 100,000 hours at temperature (vm).

IGE/TD/12

Ultimate tensile strength.

Norwegian

The material ultimate tensile strength at room temperature is Rm (lbs./sq. in.). If no value is entered, this factor is not considered to control the expansion stress allowable.