Stresses Report - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Reports stresses at each node in the model. Also reports the highest stresses and the corresponding nodes. Stresses are not computed at nodes on rigid elements or on structural steel elements. The software calculates stress components according to the piping code. For more information, see Code Stresses in the CAESAR II Quick Reference Guide.

The data fields change based on the piping code.

Multiple Piping Codes

If you analyzed the model with different piping codes, the software creates one stresses report for each code. Each report displays only the elements that were analyzed for the specific piping code.

The software filters the code compliance (pass or fail) check by piping code. If you want to see the compliance status of the entire model, run a Stresses Extended (Legacy) Report.

For offshore and transportation codes, the software determines code stress by the largest stress-to-allowable ratio. FRP pipe (ISO-14692 2017), which uses a failure envelope, also determines code stress by the largest stress-to-allowable ratio. Use the Stresses (Multiple Code/Allow) Report for these codes.