Specifies the fitting outside radius for branch connections. This option is used for reduced branch connections in the ASME and B31.1 piping codes, Bonney Forge Insert Weldolets, and for WRC 329 intersection SIF calculations. Configuration options exist to invoke the WRC 329 calculations and to limit the application of the reduced branch connection rules to unreinforced fabricated tees, sweepolets, weldolets, and extruded welding tees. If omitted, Ftg Ro defaults to the outside radius of the branch pipe.