Do not define the node number and output file if you want to manually define loads.

CAESAR II Node Number

Specifies the node number assigned to the flange pair in the piping model defined for the CAESAR II Output File. Type the optional node number.

CAESAR II Output File

Specifies an optional location of a CAESAR II piping model containing the flange pair and loads that you want to analyze.

The software uses loads from the static analysis Local Element Forces Report and assigns the correct load direction.

If the file contains one operating load case, the software determines the appropriate temperature, pressure, and material properties for each load case. The properties display on the Flange, Bolt, and Gasket tabs and in the output report.

If the file contains multiple load cases, the software determines the temperature, pressure, and material properties for each load case. The properties display in the output report, but do not display on the Flange, Bolt, and Gasket tabs.

- Specifies a file selected in a standard Open dialog box.

- Deletes a previously defined file and the load cases imported from the file.