Specifies whether a relief valve or rupture disk is used. Select RV for a relief valve. The software sets the nozzle coefficient, k, to 0.80. Select RD for a rupture disk. The software sets the nozzle coefficient, k, to 0.67. You can also enter the relieving device nozzle coefficient k if it is known.