Unif or Commands > Unif defines a constant uniform load that acts over the full length of the member and places the following card in the Card Stack pane:
Uniform loads can have special meanings when used in CAESAR II Piping runs.
If you are defining a uniform load that acts on a single element only, do not enter values for inc, incTo, and last.
Define a uniform load
-
Select the appropriate row in the Card Stack pane.
-
Use the needed command from the Insert menu to place the UNIF command in the needed position. For more information, see Insert Menu.
-
Click Unif .
The UNIF card is added to the Card Stack.
-
Click to expand the UNIF card and view the properties.
-
Add values to the UNIF properties.
-
Click Save to finish.
The CAESAR II Error Checker automatically checks the model for errors.