Piping Input menu: Options > Uniform Loads
Piping Input Legends toolbar: Uniform Loads
Static Output Processor menu: PlotOptions > Uniform Loads
Static Output Processor Plot Tools toolbar: Forces/Moments
Updates the model to show each uniform load in a different color. Use this option to see the uniform load variations throughout the system or to verify that changes have been made. A color key displays the uniform loads defined in the model. You can change the assigned colors to meet your needs.
The uniform load parameters display in a table. Use the scroll bars to view all the data. Click Next >> and Previous << to move through the displacement or force vectors.
Uniform Loads has three vectors defined. The Node column represents the start node number where the uniform loads vector was first defined. Because the data propagates throughout the model until changed or disabled, the model is colored accordingly.