Calculate Actual Cold Loads - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Indicates that CAESAR II makes one additional pass after the hanger design is completed and the hangers are installed. The pass determines the actual loads that should be used when the hangers are first installed and the load flanges adjusted in the field. This calculation tends to be important in the following situations:

  • The stiffness of the piping system is small.

  • The stiffness of the hanger selected is high.

  • The hanger travel is large. This is usually more important in smaller diameter piping systems that are spring supported away from equipment nozzles.

Actual cold loads should be calculated when springs in smaller diameter lines are to be adjusted in the cold position.