Sheath Thk - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

For ISO 14692-2017, specifies the thickness of the sheath (ts) to be applied to the piping.

Typical units (depending on your unit system):

  • in

  • mm

  • cm

The sheath is applied to the outside of the pipe. The software includes the sheath in the dead weight of the system and in the projected pipe area used for wind load computations.

1 - Diameter

2 - Wt/Sch

3 - Sheath Thk

4 - Liner Thk

5 - Total wall thickness

  • Even if you specify the unit weight of sheathing plus liner, the thickness values are still required so that the software can determine the correct projected area.

  • ISO-14692 2017 distinguishes between the reinforced wall thickness and the total wall thickness. The reinforced wall thickness does not include the liner (inside) and sheath (outside) the reinforced wall. In CAESAR II, define the reinforced dimension (not including the liner and sheath) for Diameter and Wt/Sch, and separately define Refract Thk, Refract Density, Liner Thk, and Liner Density.