Function keys help you to quickly type data without using the mouse to move to various input boxes. By default, when you place the cursor inside a box on the Classic Piping Input dialog box, pressing a function key on the keyboard moves the cursor to the beginning of a block of input data according to the list below.
Function Key |
Destination |
---|---|
F2 |
From Node |
F3 |
DX |
F4 |
Diameter |
F5 |
Temp 1 |
F6 |
Material |
F7 |
Elastic Modulus (c) |
F8 |
Refractory Thickness |
F9 |
Line number |
For additional shortcut keys used throughout the software, see Shortcut Keys.