Port Details - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
12.1 (2019)

These properties are used to specify the different port types and their sizes for the eye nut.

Port1 – RodEnd – Located at 0, 0, 0

PortType

Size

MinSize

MaxSize

1001 – IntThdRH

  • The diameter of the rod, for connecting to other components.

  • It is same as the RodDiameter property.

Not applicable for this port type. Use zero.

Not applicable for this port type. Use 9999.

1003 – IntThdLH

  • The diameter of the rod, for connecting to other components.

  • It is same as RodDiameter property.

Not applicable for this port type. Use zero.

Not applicable for this port type. Use 9999.

Port2 – Eye – Located at 0, 0, OverLength1 – InnerLength2 + PinDiameter / 2.0

PortType

Size

MinSize

MaxSize

1007 – Eye

The thickness of the eye to be compared against the opening in the connecting item. This lets you verify that the thickness of the eye fits into the opening.

It is same value as Thickness1 property.

The smallest pin or bolt that will fit inside the eye. Usually, this value is zero.

The largest pin or bolt that will fit inside the eye, from the catalog specs.

Port3 – Eye – Surface – Located at 0, 0, OverLength1 + Height1

PortType

Size

MinSize

MaxSize

1200 - Other

Not applicable for this port type. Use zero.

Not applicable for this port type. Use -9999.

Not applicable for this port type. Use 9999.