In the tree view, click Piping > Piping Specification > Model Rules > Default Change of Direction.
-
Click the Insert Row Command to insert a blank row in the grid view.
-
In the Bend Angle From column, enter the lower boundary for the bend angle. This value must match the Bend Angle To value on the previous row.
-
In the Bend Angle To column, enter the upper boundary for the bend angle. This value must match the Bend Angle From value for the next row
-
In the Functional Short Code column, enter the functional short code to use to access the piping commodity filter for the change-of-direction fitting.
The Default Change of Direction sheet in the Piping Specification.xls workbook corresponds to the Default Change of Direction node. See Piping Reference Data.