Reinforcing Weld Data - Intergraph Smart 3D - Help

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
12.1 (2019)

The Reinforcing Weld Data node (the ReinforcingWeldData sheet in the Piping Specification.xls workbook) defines the minimum reinforcing weld size to use in branch reinforcement calculations based on the header and branch size and the acute angle of the intersection between the header and the branch. This data is currently not used by the software.

Acute Branch Angle From (Required)

Enter the branch angle lower bound for which the reinforcing pad data applies. Be sure to include the unit of measurement when specifying this value.

Acute Branch Angle To (Required)

Enter the branch angle upper bound for which the reinforcing pad data applies. Be sure to include the unit of measurement when specifying this value.

Branch Size (Required)

Enter the branch size for which the reinforcing weld data applies.

Branch Size Units of Measure (Required)

Specify the units of measurement, in or mm for example, of the value you entered in the Branch Size column.

Header Size (Required)

Enter the header size for which the reinforcing weld data applies.

Header Size Units of Measure (Required)

Specify the units of measurement, in or mm for example, of the value you entered in the Header Size column.

Minimum Reinforcing Weld Size (Required)

Enter the minimum weld size of the reinforcing weld. Be sure to include the units of measurement, in or mm for example, when specifying this value.

Spec Name (Required)

Type the name of the piping materials class for which to define the reinforcing weld data. The piping materials class that you enter must be defined on the Piping Materials Classes.

See Also

Piping Materials Class Rules
Field Fit Length
Reinforcing Weld Data
Weld Clearance Rule
Weld Gap Rule
Weld Model Representation Rule
Weld Type Rule
Define Reinforcing Weld Size