Define Joint Quality Factors - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
12.1 (2019)
  1. Open the Piping Specification.xls workbook.

  2. Select the JointQualityFactor sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Spec Name column, type the name of your piping materials class.

  5. In the Nominal Piping Diameter From column, type the nominal pipe diameter (NPD) that specifies the start of the joint quality factor range.

  6. In the Nominal Piping Diameter To column, type the NPD that specifies the end of the joint quality factor range.

  7. In the NPD Unit Type column, type the units for the NPDs. For example, type mm or in.

  8. In the Joint Quality Factor column, type the joint quality factor, as a percentage, that you want to use for the defined NPD range.

  9. Save the Piping Specification.xls workbook.

The piping materials class must be defined on the PipingMaterialsClassData sheet.

See Also

Joint Quality Factor