The NPDSpecificSPREFMap sheet defines mapping between the unique string created for Smart 3D piping components and the PDMS SPREF attribute. This sheet is used if the SPREF of a component changes with a given NPD.
If no values are defined on this sheet, the software uses the values defined on the CatalogComponentSPREFMap sheet.
S3D Value
Type the Smart 3D unique string to map. The string is created by appending the Smart 3D specification name, component short code, option code, and NPD of each port. Separate each entry with a dash ( - ). For example, you can type 1C0031-Piping-1-20-20 or 1C0031-Flange-211-125-125.
PDMS Value
Type the value for the SPREF attribute to which the S3D Value setting is to be mapped.
Remarks
Provides additional comments from Intergraph on default delivered mapping.