Basic Yoke Properties - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
11 (2016)

IJUAhsDiameter1::Diameter1

Specifies the pipe diameter.

IJUAhsSize::Size (Optional)

This value is only used by the Part Selection rule for choosing a Yoke Clamp part. It is not included in the yoke clamp’s graphics.

IJUAhsPinOrLug::PinOrLug

Specifies whether the connection type is a lug or a pin.

This property uses the codelist number defined in the hsPinOrLug sheet in the HS_S3DParts_Codelist.xls.

1 - Pin

2 - Lug

3 - Top Block

IJUAhsOrientation::Orientation

Specifies how the connection type is oriented with respect to the pipe. This is applicable to both pin and lug top types.

This property uses the codelist number defined in the hsOrientation sheet in the HS_S3DParts_Codelist.xls.

IJUAhsRodTakeOut::RodTakeOut

Specifies the distance from the pipe centerline to the pin or lug centerline. This value is always greater than 0.5 times the Diameter1 plus 0.5 times the Pin1Diameter.