Define Chamfer Symbol Properties - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D 2D Symbols

Language
English
Product
Intergraph Smart 3D
Subproduct
2D Symbols
Search by Category
Reference Data
Smart 3D Version
11 (2016)

The Define Symbol Properties dialog box displays all variables and their names, values, and formulas, which remain internal to the symbol. Symbol parameters are also defined on this dialog box. These symbol properties are externalized to the Excel workbook bulkload file. Symbol parameters are externalized as either standard variables for standard symbols, or as input variables for custom symbols.

  1. On the Chamfer Symbols toolbar, click Symbol Properties . The Symbol Properties dialog box displays.

  2. Select the Parameters tab.

  3. If you want a variable to become a parameter, click on the row in the grid (the corresponding graphical dimension highlights in the symbol), and type a name in the Symbol parameter box. Click Apply after entering each parameter.

    To avoid adding multiple symbol parameters that define the same types of attributes to the catalog, naming conventions should be developed. The conventions delivered with the base catalog can be viewed on the UserAttributes worksheet of the end cut workbook. For more information, see Symbol Naming Conventions.