Enabling Ducting Integration Features - Intergraph Smart 3D - Administration

Intergraph Smart 3D Integration

Language
English
Product
Intergraph Smart 3D
Subproduct
Integration
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Before you can configure Smart 3D to retrieve ducting data from SmartPlant P&ID, the project administrator must:

  • Modify the Smart 3D catalog schema and mapping files

  • Apply the Guided Customer Schema Extensions for the Smart Plant Foundation Integration Schema

Enabling Ducting Integration Features is not available until the project administrator performs the steps below.

  1. Apply the Guided Customer Schema Extension, SPC2016SPCGSCE3, delivered on SmartSupport for SmartPlant Foundation.

  2. Run the Upgrade Schema command, and click Yes when the command prompts you to enable the ducting integration feature.

    The software updates the catalog schema database and the mapping files the necessary changes.

    For more information, see Upgrade Schema.

  3. Run the Generate Design Basis command, and enter the folder path to the component schemas generated by the Upgrade Schema command. For more information, see Generate a design basis.

  • SmartPlant P&ID uses the existing P&ID document type when you publish D&ID data from SmartPlant P&ID to SmartPlant Foundation.

  • View P&ID displays the P&ID document that contains P&ID data, and the P&ID document that contains D&ID data. For more information, see Viewing P&IDs.