BOM Revision Handling - Intergraph Smart Materials - Version 2020 (10.0) - Help - Hexagon PPM

Intergraph Smart Materials Classic Help (2020)

Language
English
Product
Intergraph Smart Materials
Subproduct
Classic
Search by Category
Help
Smart Materials/Smart Reference Data Version
2020 (10.0)

The Bill of Material (BOM) data has to be released (Isometrics) for further processing. Whenever released BOM data is changed after the release, the revision modus has to be set. For this case, the Intergraph Smart Materials BOM Revision Handling is set up. An isometric can only be released, if the user defined check procedures have been performed successfully for all positions of the isometric.

Example:

Isometric

Action

Revision

Isometric Status

ISO-A1A-1

Done

0

Not released; changes possible

ISO-A1A-1

Released

0

Released; changes not possible

ISO-A1A-1

Changes necessary

1

Increase of 1 for revision level

ISO-A1A-1

Change

1

Not released; changes possible

ISO-A1A-1

Set back to released status

1

Released; changes not possible