Option Switch 102 controls the size of the clearance gaps that occur in and around hatching. There are three of these gaps:

  • Local to the pipeline

  • Local to in-line components

  • Around dimensions and text that appear in the hatching region

Set OS 102 = 0 to define gaps at all three regions. This is the default setting.

Set OS 102 = 404040 to increase gaps at all three positions to 4mm.