The stroking tolerance affects how round surfaces such as pipes, reducers, and so on, are rendered. The larger the tolerance, the better the display quality. However, large tolerance values increase the view update time. The tolerance must be an integer between 4 and 100.

  1. Click View > Settings > View.

  2. Click the Advanced tab, and then type a Stroking tolerance.

    You also can set the stroking tolerance by clicking View > Display > Stroking Tolerance.

    During motion, the software defaults to half of the currently-specified stroking tolerance within the 4-100 limit to improve performance.