Importing transformer data requires special handling. This is due to the fact that transformers are composed of transformer and transformer component item types. Therefore the data link for transformers must provide sufficient information about the source transformers and their components. Import Manager uses the information provided in the following transformer item type properties:

Property

Setting

NumberOfSecondaries

1 - Defines a 2-winding transformer

2 - Defines a 3-winding transformer

Secondary1ItemTag

Item tag of the first transformer component - secondary winding

Secondary2ItemTag

Item tag of the second transformer component - secondary winding (used only for 3-winding transformers)

The software does not support testing of transformer links.