Member part has no attached catalog cross section definition - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

Member part has no attached catalog cross section definition.

Severity

Normal.

Detailed Description

Every member part must have only one related cross section that describes the cross section properties of the member part.

Possible Cause

Unknown.

Possible Impacts

Member property edit will fail.

What You Should Do

Follow these steps to clean the existing member parts.

  1. Open the model.

  2. Select the member part, and click Properties on the ribbon.

  3. Select the Cross Section tab.

  4. In the Section Name box, choose a section.

  5. Apply the properties.

  6. In the Section Name box, re-select the original cross section name.

  7. Apply the properties, and exit the dialog box.