A plate part does not have a related PlatePartReportData object - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

A plate part does not have a related PlatePartReportData object.

Severity

Crucial.

Detailed Description

Missing the GeometryGeneration_RSLT1 relationship to LandCurve, ProfileLandCrv, or ProfilePartPath for LandCrvIntersect_AE, LandCrvOffset_AE, LandCrvProject_AE, LandCrvTable_AE.

Possible Cause

Copying a system before Version 4.

Possible Impacts

The weight and center of gravity may not be calculated and will be invalid because the report data does not exist.

What You Should Do

  1. Delete the plate part, and re-create it.

  2. Run the stAddReport.Data.Command middle tier migration script.