A BracketByPlane PlateSystem does not have the necessary two points defined - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

A BracketByPlane PlateSystem does not have the necessary two points defined.

Severity

Crucial.

Detailed Description

A BracketByPlane PlateSystem requires two points for proper placement on the identified supports.

Possible Cause

Unknown.

Possible Impacts

The geometry and display of the PlateSystem will not be correct. This problem can affect other related objects.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the BracketByPlane PlateSystem, select the points, and make any other necessary modification.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.