Failed to create the seam point. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Object Type in the To Do List: Profile system seam point

Meaning: The seam point cannot be created on the landing curve of the profile.

Recovery:

  1. Verify that the seam point intersects with the landing curve of the profile.

  2. Select the seam point, and check the reference, offset methods, and offset distances. After verifying the seam point properties, click Finish to recompute the seam point.

Example

1 - Reference

2 - The seam point must be 1290 mm away from the reference along the girth. This exceeds the profile length. The figure shows the old seam point.