Pipe and Hanger Supported from Vessel - CAESAR II - Reference Data

CAESAR II Applications Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Reference Data
CAESAR II Version
11.0 (2019)

Connecting nodes associated with hangers and cans function in the same way as connecting nodes with restraints. Connecting node displacements are incorporated in the hanger design algorithm.

You must first disable Connect Geometry Through CNodes in the Geometry Directives category of Tools > Configure/Setup. For more information, see "Configuration and Environment" in the CAESAR II User's Guide.