Relief Valve Loads (RELIEF) - CAESAR II - Reference Data

CAESAR II Applications Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Reference Data
CAESAR II Version
11.0 (2019)

The following example analyzes the two relief valve systems, shown below, subject to the simultaneous firing of both valves.

  • Process Steam Conditions - 450 psi, @ 650°F

  • Relief Valve Orifice - JOHNSON #34A-06 2.141 in. ID.

  • Valve Opening Time - 8.0 milliseconds

  • Valve Closing Time - 8.0 milliseconds

  • Relief Duration - 1.0 second