Meaning: The nozzle placement type is set to either Skew or Offset Skew. The value for N2 cannot be less than or equal to the value for N3 for these placement types.
Recovery:
-
Set the Locate Filter to the nozzle type.
-
Select the nozzle in error.
-
Click Edit > Properties.
-
Click the Location tab.
-
Change the value for N2 to be greater than the value for N3. Or, change the placement type, and define new placement values.