Special Instructions - Intergraph Smart P&ID - Release Bulletin - Intergraph

SmartPlant P&ID Release Bulletin

PPMProduct
Intergraph Smart P&ID
PPMCategory_custom
Release Bulletin
Version_SPPID_custom
2014 (7.0)
Version_SPEM_custom
7.0.0

From SmartPlant P&ID 2014, Oracle 10 is no longer supported.

License Manager

SmartPlant P&ID 2014 requires the installation of SmartPlant License Manager (SPLM) 2010 Client (11.00) or 2012 Client (12.00)

Intergraph Smart® 3D SP3DPIDClient Installation

If you are installing Intergraph® Smart 3D SP3DPIDClient, you must first uninstall any previous installation of SmartPlant 3D Piping Specification Remote Access Client.

Upgrading from a Previous Version of the Software

  • After upgrading to the latest version of SmartPlant P&ID, opening Options Manager for the first time updates the RAD version for the ProjectStyles.spp file and as a result, changes the status of the Symbology for the drawings to 'Out-of-Date'. For this reason, after upgrading SmartPlant P&ID, you should open and close Options Manager once before updating your drawings using SmartPlant P&ID Drawing Manager.

  • After upgrading to the latest version of SmartPlant P&ID, you should open and close Rule Manager once before updating your drawings using SmartPlant P&ID Drawing Manager. This ensures that the Rules.rul file is updated with the new rules.

  • In an integrated environment, when synchronizing the schemas in Version 2009 SP2 or lower and then upgrading to Version 2009 SP3 or higher, duplicate relations may be generated, resulting in schema errors. To resolve this issue, you should perform schema validation using Schema Editor to identify the duplicate relations and then delete the duplicates.