Connection - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Structural Manufacturing Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Structural Manufacturing
Search by Category
Reference Data
Smart 3D Version
12.1 (2019)

Unknown Host

connection_unknown host_windows service

Follow these steps if you encounter the message No such host is known, as shown in the example above.

  1. Open the S3DLoopBackClient.exe.config file using a text editor, and verify that the Listener computer name and the IP address are correct. Close the file. For information on these settings, see Setting up the Client_Windows Service.

  2. In Control Panel, click Administrative Tools, and then click Services. Verify that the Intergraph Smart 3D LoopBack Listener Service is started; click Start if the service is not started. For information on starting the service, see Setting up Nesting LoopBack_Windows Service. In the example below, the service is started.

    Services_LoopBack_Listener_Service

No Connection

connection_no connection_windows service

Follow these steps if you encounter the message No connection could be made because the target machine actively refused it [IP address:Port Number], as shown in the example above.

  1. Verify that the IP address is defined correctly. For information about the correct settings, see Setting up the Client_Windows Service.

  2. Verify that the configuration port numbers are defined correctly. For information about the correct settings, see Defining Configuration Ports__Windows Service.