The Ref Curve PG does not match root system PG - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12.1 (2019)

Message

The Ref Curve PG does not match root system PG.

Severity

High.

Detailed Description

The Ref Curve permission group does not match the root system permission group. For example, the permission group for the reference curves of the hull does not match the permission group for the hull.

Possible Cause

Unknown.

Possible Impacts

You cannot manipulate the object itself or other objects related to it.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. In the software, click Tools > Custom Commands, and run the Clean Database custom command.

  3. Select the object(s) to be repaired.

  4. Click Clean Now.

  5. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  6. If the object is still posted, contact Smart 3D Support.